Cain Boiler Economizer Specifications Related Information

Boiler Economizer Exhaust Heat Recovery Systems - Cain Ind

11 rows · Our broad line of economizers covers the spectrum of boiler sizes ranging from very small hot ...

Cain Industries - Fin Coil Recovery Economizer

Cain Industries - Fin Coil Recovery Economizer. Details. ... High efficiency wear resistance separation efficiency 98% effectively improve the combustion efficiency of the boiler thermal efficiency. Large furnace design Large furnace low velocity design; the application of wearproof tube technology reducing erosive abrasion. ...

Cain DXL Boiler Economizer Messplay Machinery Co.

What makes the DXL Boiler Economizer unique is that it recovers heat in two stages. The first stage will preheat boiler feedwater and the second stage will preheat boiler make-up water. Final exhaust temperatures leaving typically range from 120°F 170°F.

Cleaver-Brooks - C2X Economizer

Boilers up to 2500 HP. Accommodates all boiler design pressures. The C2X two-stage Condensing Economizer is a condensing economizer that captures heat through both a traditional stack economizer section and a condensing section. Can be utilized on boilers up

Cain CXL Boiler Economizer Messplay Machinery Co.

Cain CXL Boiler Economizer The CXL Single Stage Condensing Exhaust Economizer is specifically designed to recover sensible heat from within the exhaust and more importantly to also recover additional valuable latent heat as the exhaust is condensed.

Cain EM Boiler Economizer Messplay Machinery Co.

Cain EM Boiler Economizer The EM is designed to recover heat from combustion sources with atmospheric burners from 200 to 6400 MBH. Ten standard models are designed to operate with low static gas pressure drop for safe automatic operation on atmospheric or power burners.

Cain Industries - Two Stage Condensing Economizer ...

Steam boilers hot water boilers and hot oil heaters with inputs up to 250000000 BTU/hr. Boiler Exhaust Application Capacity: up to 250000 lb/hr steam Entering Gas Temps: 300°F to 800°F Heat Sink Types: boiler feedwater makeup water hot water return hot water storage tank condensate tank process water. Features. Internal expansion design

ASME - International Boiler and Pressure Vessel Code

and high temperature water boilers intended for operation at pressures exceeding 160 psig and or temperatures exceeding 250 degree F. Superheaters economizers and other pressure parts connected directly to the boiler without intervening valves are considered as part of the scope of Section 1. II. Materials. Part A-Ferrous Material Specifications

Cain Industries - Fin Coil Recovery Economizer

Cain Industries - Fin Coil Recovery Economizer. Details. ... High efficiency wear resistance separation efficiency 98% effectively improve the combustion efficiency of the boiler thermal efficiency. Large furnace design Large furnace low velocity design; the application of wearproof tube technology reducing erosive abrasion. ...

Cain Industries RTR Boiler Economizer Messplay Machinery Co.

Cain Industries RTR Boiler Economizer The RTR is ideal for large steam boilers and hot water boilers. The RTR has individual fin tubes compression fitted to the liquid manifold for ease of tube replacement requiring no welding.

Boiler Economizer-Cain-FCR-FIN Series Demo-Cain-FCR-FIN ...

Boiler Economizer-Cain-FCR-FIN Series Capacity: 40 500 BHP (50 -10000 SCFM) Entering gas temps: to 800°F Heat sink types: Boiler feedwater process water thermal fluids run-around systems FEATURES Internal thermal expansion design Cylindrical heat transfer coil (s) design Mounting ...

Cain Industries - Rectangular Tube Recovery Economizer ...

Steam boilers hot water boilers hot oil heaters with inputs up to 250000000 BTU/hr. Boiler Exhaust Application. Capacity: up to 250000 lb/hr steam. Entering Gas Temps: 300°F to 800°F. Heat Sink Types: boiler feed water makeup water hot water return hot water

Cain CXL Boiler Economizer Messplay Machinery Co.

Cain CXL Boiler Economizer The CXL Single Stage Condensing Exhaust Economizer is specifically designed to recover sensible heat from within the exhaust and more importantly to also recover additional valuable latent heat as the exhaust is condensed.

Cain FCR Boiler Economizer Messplay Machinery Co.

Cain FCR Boiler Economizer The FCR is a custom-designed heat exchanger which can be applied in confined areas and is offered in stainless steel carbon steel or AL-FUSE finned tubing. Design flexibility allows specific engineering requirements to be met such as fin spacing for fouling conditions and low gas pressure drops.

Cain Industries | DXL Two Stage Condensing Boiler Economizer

Steam boilers hot water boilers and hot oil heaters with inputs up to 250000000 BTU/hr. (natural gas fired) Boiler Exhaust Application Capacity: up to 250000 lb/hr steam Entering Gas Temps: 300°F to 800°F Heat Sink Types: boiler feedwater makeup water hot water return hot water storage tank condensate tank process water

Cain Industries - Fin Coil Recovery Economizer

Cain Industries - Fin Coil Recovery Economizer. Details. ... High efficiency wear resistance separation efficiency 98% effectively improve the combustion efficiency of the boiler thermal efficiency. Large furnace design Large furnace low velocity design; the application of wearproof tube technology reducing erosive abrasion. ...

Exhaust Heat Recovery Systems | Cogeneration | Boiler

Boiler Economizer Systems Facts Without Cain Economizer: Most boilers have a combustion efficiency of 78-82%. Boiler exhaust temperatures exiting into the atmosphere: 350º - 600º F. Stack energy loss is typically 18-22%. With Cain Economizer: Efficiency is increased reducing fuel costs. Average efficiency increase is 4-7%.